| Sign In | Join Free | My burrillandco.com | 
              
  | 
      
| Ask Lasest Price | |
| Brand Name : | CITY | 
| Model Number : | Micropel 75C SR-W-MP75C | 
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability : | 5000pcs/Month | 
| Delivery Time : | 3-5Workingdays | 
| Price : | Negotiable | 
SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
How it works: catalytic oxidation
Range: 0-100% LEL
Sensitivity: 31 ± 5 mV/% methane
T90 response time: <5 seconds (methane)
Operating temperature range: -20°C to +55°C
Operating humidity range: 0-90% RH without condensation
Specification:
| Product Type | MICROpel 75C | 
| Operating Principle | Catalytic Oxidation | 
| Gases Detected | Combustible gases | 
| Suitable for | Methane, ethane, propane, butane, pentane, hexane, carbon monoxide & hydrogen  | 
| Unsuitable for | Higher hydrocarbons, alcohols, ketones, esters, hydrogen sulfide and other sulfur containing compounds  | 
| Range | 0-100% LEL | 
| Sensitivity | 31 ± 5 mV/%methane | 
| T90 Response Time | <5 seconds (methane) | 
| Poison Resistance | Resistance to H2S poisoning Superior silicone resistance  | 
| H2S Filter Lifetime | Typically 1000 ppm hr | 

                                 
                             |