| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | Alphasense |
| Model Number : | Cl2-B1 |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability : | 3000PCS/Months |
| Delivery Time : | 3-5work days |
| Price : | Negotiable |
Product Description:
Cl2-B1 Chlorine Gas Sensor CL2 Sensor Electrochemical New
Features:
Typical application of electrochemical chlorine gas sensor CL2-B1
Electrochemical chlorine gas sensor CL2-B1 applied to sewage treatment, industrial environment toxic gas measurement performance sensitivity 10ppmCL2, nA/ PPM-600 ~-1150
Reaction time t90 from zero to 10ppmCL2 (s) < 60
PPM content of zero point current in zero point air ±0.2
Resolution Average noise (PPM) (33 ω load) & LT; 0.02
Main parameters of electrochemical chlorine gas sensor CL2-B1
Specifications:
| Sensitivity | -600 ~ -1150Na/PPM |
| Response time | < 60s |
| Linear range | 20ppm |
| Overload | 60 PPM |
| Resolution | 0.02 PPM |

|