Sign In | Join Free | My burrillandco.com
Home > Oxygen Gas Sensor >

MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery from wholesalers
     
    Buy cheap MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery from wholesalers
    • Buy cheap MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery from wholesalers
    • Buy cheap MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery from wholesalers

    MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery

    Ask Lasest Price
    Brand Name : CITY
    Model Number : MOX-4 MOX4 AA829-M20
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000pcs/Month
    Delivery Time : 3-5work days
    Price : Negotiable
    • Product Details
    • Company Profile

    MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery

    Product Description:

    MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery


    Features:

    The purpose of this document is to present the performance specification of the MOX4 oxygen gas sensor.

    This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

    The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

    Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

    Poisoning

    CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.

    When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

    Intended Use

    These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators and general oxygen monitors


    Specifications:

    Operating PrinciplePartial pressure electrochemical
    Output9 mV to 13 mV in 210 mBar O2
    Measurement Range0 mBar to 1500 mBar O2
    Response Time (T90)*<15 s (air to 100% O2)
    Baseline Offset*<200 μV
    LinearityLinear 0% to 100% O2

    MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery

    Quality MOX4 MOX-4 AA829-M20 Oxygen Gas Sensor Medical Equipment White ABS Battery for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)