Sign In | Join Free | My burrillandco.com
burrillandco.com

ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Verified Supplier

4 Years

Home > Gas Sensor >

ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
     
    Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
    • Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
    • Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
    • Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
    • Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers
    • Buy cheap ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems from wholesalers

    ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems

    Ask Lasest Price
    Model Number : ZE07-H2
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000PCS
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems


    ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems


    1. Product Overview:

    The ZE07-H2 is a high-performance, electrochemical-type hydrogen (H₂) gas sensor designed for accurate detection of hydrogen gas concentrations in air. It features small size, low power consumption, and stable output, making it suitable for various industrial, commercial, and residential hydrogen leak monitoring scenarios.

    2. Key Features:

    • Electrochemical Sensing Principle: Offers high selectivity to H₂, minimizing interference from common gases (e.g., CO, CH₄, ethanol).
    • Wide Detection Range: Covers typical hydrogen leak and monitoring needs (see "Electrical Specifications" for details).
    • Low Power Consumption: Suitable for battery-powered or low-power embedded systems.
    • Fast Response & Recovery: Rapidly detects H₂ concentration changes and returns to baseline quickly after gas removal.
    • Analog Output: Provides linear analog voltage output proportional to H₂ concentration for easy signal acquisition.
    • Compact Design: Small form factor enables integration into portable detectors or compact monitoring devices.
    • Long Service Life: Industrial-grade components ensure stable performance and extended operational lifespan.

    3. Installation & Usage Notes:

    1. Gas Exposure: Avoid prolonged exposure to H₂ concentrations exceeding the full-scale (FS) range, as this may damage the sensor and shorten its service life.
    2. Environmental Protection: Do not install the sensor in areas with condensation, heavy dust, or corrosive gases (e.g., Cl₂, H₂S), as these will interfere with performance.
    3. Calibration: Perform regular calibration (recommended every 6–12 months) using a standard H₂ gas source to maintain detection accuracy.
    4. Signal Processing: The analog output requires a low-pass filter (e.g., 100 Hz RC filter) to reduce noise; for digital UART output, ensure correct baud rate (typically 9600 bps) and communication protocol matching.
    5. Power Supply: Use a stable DC power supply to avoid voltage fluctuations affecting the sensor’s output stability.

    Parameter

    Specification

    Sensing GasHydrogen (H₂)
    Sensing PrincipleElectrochemical
    Detection RangeTypically 0–1000 ppm (adjustable for 0–4000 ppm based on model variants)
    Resolution≤ 1 ppm
    Accuracy±5% FS (Full Scale) at 25°C, 1 atm
    Response Time (T₉₀)≤ 30 seconds
    Recovery Time (T₁₀)≤ 60 seconds
    Output SignalAnalog Voltage: 0.4–2.0 V (corresponding to 0–FS concentration); Optional UART digital output
    Operating Voltage3.3 V DC ± 0.1 V or 5.0 V DC ± 0.2 V (varies by model; confirm with supplier)
    Operating Current≤ 20 mA (typical: 15 mA)
    Operating Temperature-10°C to +50°C (optimal: 0°C to +40°C)
    Operating Humidity15% RH to 85% RH (non-condensing)
    Storage Conditions-20°C to +60°C, 10% RH to 90% RH (non-condensing); avoid corrosive gases
    Service Life≥ 2 years (under normal operating conditions; not exposed to H₂ above FS)
    Dimensions (L×W×H)Typically 20 mm × 16 mm × 6 mm (SMD package) or 22 mm × 18 mm × 7 mm (DIP package); confirm with supplier
    Gas InletDiffusion-type (no pump required; ensure adequate air flow around the sensor)

    ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems

    Quality ZE07-H2 Hydrogen Gas Sensor For Portable Hydrogen Leak Detectors Fixed Hydrogen Monitoring Systems for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)