Sign In | Join Free | My burrillandco.com
burrillandco.com

ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Verified Supplier

4 Years

Home > Gas Sensor >

ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices from wholesalers
     
    Buy cheap ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices from wholesalers
    • Buy cheap ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices from wholesalers

    ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

    Ask Lasest Price
    Model Number : ZE08-CH2O
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000PCS
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices


    ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices


    1. Product Overview:

    The ZE08-CH2O is a high-precision electrochemical formaldehyde (CH₂O, also known as formaldehyde) gas sensor, specifically engineered for real-time detection of formaldehyde concentrations in indoor and outdoor air. It integrates advanced electrochemical sensing technology to deliver stable, selective, and low-power performance, making it ideal for applications requiring accurate formaldehyde monitoring—such as indoor air quality (IAQ) assessment and safety systems.

    2. Key Features:

    • High Selectivity: Utilizes an electrochemical sensing cell optimized for CH₂O, effectively minimizing interference from common background gases (e.g., CO, CO₂, ethanol, methane, and volatile organic compounds/VOCs like benzene).
    • Low Detection Limit: Capable of detecting trace formaldehyde concentrations, meeting strict indoor air quality monitoring requirements.
    • Linear Output: Provides a linear analog or digital output signal proportional to CH₂O concentration, simplifying data acquisition and processing for microcontrollers (MCUs) or embedded systems.
    • Low Power Consumption: Designed for battery-powered devices (e.g., portable IAQ monitors) with minimal current draw.
    • Compact Form Factor: Small SMD or DIP package enables easy integration into compact devices (e.g., smart air purifiers, wearable sensors).
    • Long-Term Stability: Industrial-grade components and advanced encapsulation technology ensure consistent performance and extended service life under normal operating conditions.
    • Fast Response & Recovery: Rapidly responds to changes in CH₂O concentration and returns to baseline quickly after the gas is removed.

    3. Typical Applications:

    • Indoor Air Quality (IAQ) Monitors: Residential, office, or school IAQ devices to detect formaldehyde from furniture, paints, or adhesives.
    • Smart Home Devices: Integration with smart air purifiers, thermostats, or safety hubs to trigger alerts/ventilation when CH₂O exceeds safe levels.
    • Portable Detectors: Handheld devices for homeowners, inspectors, or renters to test indoor formaldehyde concentrations.
    • Industrial Monitoring: Low-concentration CH₂O detection in furniture manufacturing, textile printing, or chemical plants (where formaldehyde is used as a raw material).
    • Medical & Commercial Spaces: Monitoring in hospitals, hotels, or childcare centers to ensure compliance with health and safety standards.

    4. Installation & Usage Notes:

    1. Avoid Contamination: Do not install the sensor in areas with heavy dust, oil mist, or corrosive gases (e.g., Cl₂, H₂S, ammonia), as these will damage the sensing cell and cause false readings.
    2. Condensation Prevention: Ensure the operating environment remains non-condensing. Use a moisture barrier or ventilation if installing in high-humidity areas (e.g., bathrooms, kitchens).
    3. Calibration: Always calibrate the sensor before first use and at the recommended interval (6–12 months) using a certified formaldehyde standard gas (e.g., 0.5 ppm CH₂O in air). Uncalibrated sensors may drift over time.
    4. Signal Filtering: For analog output, add a low-pass filter (e.g., 100 Hz RC filter) to reduce electrical noise and stabilize readings.
    5. Power Supply Stability: Use a regulated DC power supply to avoid voltage fluctuations, which can cause output instability.
    6. Preheating Time: Allow the sensor to preheat for 3–5 minutes after power-on to ensure stable baseline readings before taking measurements.

    Parameter Category

    Parameter Name

    Specification

    Unit

    Remarks

    Target Gas & Sensing PrincipleTarget GasFormaldehyde (CH₂O)-Specialized for CH₂O detection; no cross-sensitivity to common VOCs (e.g., benzene, ethanol)
    Sensing PrincipleElectrochemical (Three-Electrode Structure: Working/Counter/Reference)-Enhances selectivity and reduces long-term drift
    Measurement PerformanceDetection RangeStandard: 0 ~ 1 ppm; Optional: 0 ~ 5 ppmppm0~1 ppm for indoor air quality (IAQ); 0~5 ppm for industrial scenarios
    Resolution≤ 0.01 (for 0~1 ppm range); ≤ 0.05 (for 0~5 ppm range)ppmMinimum detectable concentration change
    Accuracy±5% FS (at 25℃, 1 atm, 50% RH); ±10% FS (at -10℃/+50℃, 15%/85% RH)-FS = Full Scale; tested with 0.5 ppm CH₂O standard gas
    Response Time (T90)≤ 30SecondsTime to reach 90% of stable output signal
    Recovery Time (T10)≤ 60SecondsTime to drop to 10% of stable output signal
    Electrical CharacteristicsPower Supply VoltageOption 1: 3.3 ± 0.1 V DC; Option 2: 5.0 ± 0.2 V DCV (DC)Select voltage based on device power design; use regulated power
    Operating Current≤ 20 mA (typical: 15 mA); Standby Current (optional): ≤ 5 mAmALow current supports battery-powered portable devices
    Output Signal TypeOption 1: Analog (0.4 ~ 2.0 V DC, linear with concentration); Option 2: Digital (UART, 9600 bps, 8N1)-Analog for simple integration; UART for data logging
    Zero Drift (Annual)≤ 3% FS-In clean air (CH₂O < 0.01 ppm); drift increases in high-humidity environments
    Environmental AdaptabilityOperating Temperature Range-10 ~ 50Optimal range: 0 ~ 40℃ for best accuracy
    Storage Temperature Range-20 ~ 60Store in dry, CH₂O-free environment; avoid direct sunlight
    Operating Humidity Range15 ~ 85% RHNon-condensing; condensation damages the sensing electrode
    Atmospheric Pressure Range86 ~ 106kPaSuitable for low-to-medium altitude areas (≤ 1500 meters)
    Mechanical & Physical SpecsHousing/Package TypeOption 1: SMD (Surface-Mount Device); Option 2: DIP (Dual In-line Package)-SMD for compact devices; DIP for easy prototyping
    Overall Dimensions (L×W×H)SMD: 20 × 16 × 6 mm; DIP: 22 × 18 × 7 mmmmExcludes pins/connectors; refer to 2D drawing for exact size
    WeightSMD: ≤ 5 g; DIP: ≤ 8 ggNet weight (no cables/fittings)
    Gas Intake ModeDiffusion (Passive)-No external pump required; ensure 5+ mm clearance for airflow
    Lifespan & MaintenanceTypical Operational Lifespan≥ 2YearsUnder normal use (no exposure to CH₂O > FS, no dust/condensation)
    Calibration Interval6 ~ 12

    ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices

    Quality ZE08-CH2O High-precision Electrochemical Formaldehyde Gas Sensor For Indoor Air Quality (IAQ) Monitors Smart Home Devices for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)