| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | Figaro |
| Model Number : | TGS2610-C00 TGS2610-D00 |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability : | 5000pcs |
| Delivery Time : | 3-5work days |
TGS2610-C00 TGS2610-D00 Flammable gas sensor Liquefied petroleum gas sensor
Features:
* Low power consumption
* High sensitivity to LP and its component gases (e.g. propane and
butane)
* Long life and low cost
* Uses simple electrical circuit
Applications:
* Residential LP leak detectors and alarms
* Portable LP detectors
* LP gas and vapor detection
TGS2610 is a semiconductor type gas sensor which combines very high sensitivity to LP gas with low power consumption and long life. Due
to miniaturization of its sensing chip, TGS2610 requires a heater
current of only 56mA and the device is housed in a standard TO-5 package.
The TGS2610 is available in two different models which have
different external housings but identical sensitivity to LP gas. Both models are able
to satisfy the requirements of performance standards such as UL1484 and EN50194.
TGS2610-C00 possesses small size and quick gas response, making it
suitable for gas leakage checkers.
TGS2610-D00 uses filter material in its housing which eliminates
the influence of interference gases such as alcohol, resulting in highly
selective response to LP gas. This feature makes the sensor ideal for residential gas
leakage detectors which require durability and resistance against
interference gas.
The figure below represents typical sensitivity characteristics,
all data having been gathered at standard test conditions (see
reverse side of this sheet). The Y-axis is indicated as sensor
resistance ratio (Rs/Ro) which is defined as follows:
Rs = Sensor resistance in displayed gases at various concentrations
Ro = Sensor resistance in 1800ppm of iso-butane
| Heater resistance | approx. 59Ω at room temp. |
| Sensor resistance | 0.68~6.8kΩ in 1800ppm iso-butane |
| Sensitivity (change ratio of Rs) | 0.56 ± 0.06 |
| Test gas conditions | Iso-butane in air at 20±2˚C, 65±5%RH |
| Circuit conditions | VC = 5.0±0.01V DC VH = 5.0±0.05V DC |
| Conditioning period before test | 7 days |


|