Air Flow Sensor AWM5101VN
Features:
Linear voltage output
Venturi design
Remote mounting capability
Active laser trimming improves interchangeability
Separate gas calibration types:-Ar (argon)-N2 (nitrogen) or -CO2 (carbon dioxide)
Potential Applications :
Damper control for heating, ventilation, and air conditioning systems
Gas analyzers
Low vacuum control
Process control
Medical respirators and ventilators
Oxygen concentrators
Leak detection equipment
Vent hoods
Anesthesia control
Gas metering
Gas chromatography
Description
In-Line Flow Measurement
AWM5000 Series Microbridge Mass Airflow Sensors feature a Venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25" H2 O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging.
| Maximum change in flow rate | 5.0 SLPM/s |
| Max. Repeatability & Hysteresis Error | ±0.50% Reading |
| Null Offset | 0.95 Vdc min., 1 Vdc typ., 1.05 Vdc max. |
| Response Time | 60 ms max. |
| Supply Voltage | 8.0 Vdc min., 10.0 Vdc typ., 15.0 Vdc max. |
| Maximum Common Mode Pressure | 50.0 psi |
| Power Consumption | 100 mW max. |
| Operating Temperature Range | -20 °C to 70 °C [-4 °F to 158 °F] |
| Storage Temperature Range | -20 °C to 70 °C [-4 °F to 158 °F] |
| Media Compatibility | Dry gas only |


|