MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
     
    Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
    • Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
    • Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
    • Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
    • Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers
    • Buy cheap MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings from wholesalers

    MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings

    Ask Lasest Price
    Model Number : MOX-2 MOX2 AA829-220
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 3-5work days
    • Product Details
    • Company Profile

    MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings

    MOX2 Oxygen Sensor
    Part Number: AA829-220


    Document Purpose:
    The purpose of this document is to present the performance specification of the MOX2 oxygen gas sensor.
    This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).
    The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.
    Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).


    Important Note:

    Connection should be made via recommended mating parts only.
    Soldering to the sensor will damage it and invalidate the warranty.
    For further information on the external load resistance and connection to the
    recommended mating part, please see Operating Principle OP-04 or contact City
    Technology.
    All performance data is based on measurements made with cylinder gases using
    a flow rate of 100 mls/min. Conditions at 20°C, 50% RH and 1013 mBar. For sensor
    performance data under other conditions, contact City Technology.
    Performance characteristics outline the performance of sensors supplied within the
    first 3 months. Output signal can drift below the lower limit over time.


    Poisoning:
    CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is
    important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting
    into instruments and operation.
    When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the
    sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.


    Intended Use:
    These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not
    including xenon), critical care, neonatal incubators, and general oxygen monitors.


    Stabilisation Time:
    Allow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturers
    instructions.


    Cleaning and Sterilisation:
    In case of contamination the sensor may be cleaned with distilled water and allowed to dry naturally.
    The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or
    hydrogen peroxide.


    Typical ApplicationsCritical care anesthesia
    Operating Temperature Range-20°C to +50°C
    Operating Pressure Range0.5 Bar to 2.0 Bar
    Operating Humidity Range0% to 99% RH noncondensing
    Long-Term Ouput Drift in 100% O2< 5% signal loss/year

    MOX-2 AA829-220 Electrochemical Gas Sensor for Oxygen Concentration Monitoring in Medical Settings