Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | CITY |
Model Number : | 7HH AC702-400 |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 2200 |
Delivery Time : | 3 days |
Product Description:
7H Electrochemical 7 Series Hydrogen H2 Sensor
Features:
CiTiceLs may exhibit a response to certain gases in a sample other than the target gas. 7H CiTiceLs have been tested
with a number of commonly cross-interfering gases and the results are given below. The table shows the typical
response to be expected from a sensor when exposed to a given test gas concentration (relevant to safety, e.g. TLV
levels).
Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with the company’s policy of continued product improvement
City Technology Limited reserves the right to make product changes without notice. No liability is accepted for any consequential losses, injury or damage resulting
from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitute a specification or an offer for
sale. The products are always subject to a programme of improvement and testing which may result in some changes in the characteristics quoted. As the products
may be used by the client in circumstances beyond the knowledge and control of City Technology Limited, we cannot give any warranty as to the relevance of
these particulars to an application. It is the clients’ responsibility to carry out the necessary tests to determine the usefulness of the products and to ensure their
safety of operation in a particular application.
Performance characteristics on this data sheet outline the performance of newly supplied sensors. Output signal can drift below the lower limit over time.
Specifications:
Measurement Range | 0-50ppm |
Maximum Overload | 500ppm |
Output Signal | 0.37 ± 0.07 μA/ppm |
T90 Response Time | <35 Seconds |
![]() |