| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Model Number : | A5F+ |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Delivery Time : | 3-5work days |
A5F+ Electrochemistry Carbon Monoxide Gas sensor For Carbon Monoxide Gas Analyzer And Alarm
Cross-sensitivity Data:
CiTiceLs may exhibit a response to certain gases in a sample other
than the target gas. The table below shows
the typical response of A5F+ sensors to a number of common
cross-interfering gases. The figures are expressed
as a percentage of the primary sensitivity (i.e. nitric oxide =
100%).
| Pressure Range | Atmospheric ± 10% |
| Pressure Coefficient | 0.010% signal/mbar |
| T90 Response Time | < 30 seconds |
| Relative Humidity Range | Relative Humidity Range |
| Typical Net Baseline Range (pure air) | -2 to +17 ppm equivalent |
| Maximum Net Zero Shift (+20°C to +40°C) | 5 ppm CO equivalent |
| Long Term Output Drift | <2% signal loss/month |
| Recommended Load Resistor | 10Ω |

|