| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Model Number : | 4COSH |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Delivery Time : | 3-5workingdays |
4COSH Carbon Monoxide / Hydrogen Sulfide (CO / H2S) Dual Gas Sensor Part Number: ABC05-800
IMPORTANT NOTE: Connection should be made via
PCB sockets only. Soldering to the pins will seriously
damage your sensor and invalidate the warranty.
* Specifications are valid at 20°C, 50% RH and 1013 mBar, using
City Technology
recommended circuitry. Performance characteristics outline the
performance of sensors
supplied within the first 3 months. Output signal can drift below
the lower limit over time.
| Storage Life | 6 months in CTL container |
| Expected Operating Life | 3 years in air |
| Long Term Sensitivity Drift | <30% signal loss/operating life |
| Operating Humidity Range | 15 - 90% RH non-condensing |
| Operating Pressure Range | Atmospheric ± 10% |

|